Jerol traffic signal posts can be supplied in 114mm, 168mm or 219mm diameter.
The size and diameter of the traffic signal posts required are determined from the matrix below.

There are 2 basic methods of connecting the traffic signal posts; head cables to the incoming plug and socket cable.

Dependent upon the type of cabling used this connection can either be achieved by a termination box located on the backboard in the door opening OR by an external termination box, mounted on the outside of the traffic signal posts, just above, and to the rear of the door opening.

The incoming supply cable is connected to the plug and socket by the electrical enclosure, which is mounted in an access chamber.

Comparison of Jerol signal post permitted deflections at WL6 wind
pressure 1.4kN/m 2 (All in mm)
Configeration
1a
1b
2a
2b
3a
3b
4a
4b
5
6
Height above ground m
5.3
5.3
4.8
4.8
4.3
4.3
3.3
3.3
5.3
4.8
Signal head arrangement
4 top
4 low
2 top
2 low
4 top
4 low
2 top
2 low
4 top
2 top
4 top
2 top
4 top
4 top
Actual deflection 114 mm dia post - no door
936
502
703
372
390
210
146
78
821
578
Actual deflection 114mm dia post with door
998
535
750
397
416
220
156
83
876
617
Actual deflection 168mm dia post - no door
236
125
177
92
100
54
38
20
211
149
Actual deflection 168mm dia post with door
252
133
189
98
107
58
40
21
225
159
Actual deflection 219 mm dia post - no door
101
54
75
39
43
24
16
9
92
64
Actual deflection 219 mm dia post with door
108
57
80
42
46
25
17
9
98
69
2% Permitted under EN 12368
(on total length)
120
120
110
110
100
100
80
80
120
110
2.5% permitted under EN 12899-1 TDB4
(on above ground)
132.5
132.5
120
120
107.5
107.5
82.5
82.5
132.5
120
5% permitted under EN 12899-1 TDB5
(on above ground)
265
265
240
240
215
215
165
165
265